JCB3-80H Miniature Circuit Breaker 10kA
JCB3-80H Miniature Circuit Breakers for use in domestic installations, as well as commercial and industrial distribution systems
Exclusive design for your safety!
Short circuit and overload protection
Breaking capacity up to 10kA
With contact indicator
Can be made from 1A to 80A
1 Pole, 2 Pole, 3 Pole , 4 Pole are available
B , C or D curve
Comply with IEC 60898-1
Introduction:
JCB3-80H Miniature Circuit Breakers is our energy-restricting circuit-breaker that has high performance values and that is equally suitable for the industrial sector, for commercial use and for installation at home. If a short-circuit occurs, it guarantees excellent selectivity conditions to upstream overcurrent circuit breakers while the load on equipment that is connected downstream is limited to a minimum amount.
JCB3-80H MCBs in accordance with standard EN 60898-1.This standard is for electrical installation material for household installations and for similar purposes.
JCB3-80H Circuit Breakers offer the fastest, and most flexible installation experience and completely eliminates safety concerns during maintenance and operation.they are engineered to adapt to the most challenging networks and environments while remaining cost effective over time. Once a fault is detected, the miniature circuit breaker automatically switches off the electrical circuit to prevent damage to wires and to avoid the risk of fire
JCB3-80H Circuit breaker has a unique bottom-fixing auxiliary contact for saving space and time. It is designed for fast installation, reliability, and superior circuit protection.
JCB3-80H MCB offers the right high performance MCB with high-rated breaking capacities and various tripping characteristics.High nominal current range of up to 80A.
JCB3-80H MCBs can be made with B, C, D type. Type B tripping characteristic: the tripping current is (3 ~ 5) In, which is suitable for household distribution system, household appliances protection and personal safety protection. Type C tripping characteristic: the tripping current is (5-10) In, which is suitable for protecting distribution lines, lighting lines and motor circuits with high connecting current. Type D tripping characteristic: the tripping current is (10 ~ 20) In, which is suitable for protecting equipment with high impulse current, such as transformer, solenoid valve, etc.
JCB3-80H MCB is used for overload and short-circuit protection of lighting, distribution lines, equipment in office buildings, residential buildings and etc. It can also be used for infrequent on-off operations and conversion of lines.
Product Description:
The most important features
● High rated Breaking capacity up to 10kA
● Short-circuit protection
● Overload protection
● With contact indicator, green=off, Red=ON
● High nominal current range of up to 80A
● Optimum ease of installation and connection
● 1 Pole, 2 Pole, 3 Pole , 4 Pole are available
● B , C or D curve are available
● 35mm Din rail mounted
● Comply with IEC 60898-1
Function
● Protection of circuits against short-circuit currents;
● Protection of circuits against overload currents;
● Switch;
● Isolation
Application
1) Public buildings
Schools, hospitals, office buildings: Wherever there are large numbers of people coming and going, reliable power supplies are of importance. JCB3-80H High Performance MCBs ensure that personal injury and damage to property are avoided in the event of short-circuits
2) Airports
Millions of people take off here. Day in, day out. JCB3-80H High Performance MCBs ensure that personal injury and damage to property are avoided in the event of short-circuits
3) Alternative energies
Simply inexhaustible: more and more power stations operating on the based on renewable energy, such as solar power, are being built around the world. JCB3-80H High Performance MCBs ensure safer operations
4) Power stations
Virtually nothing runs without electricity. With a total of more than 3 400 000 megawatts of power, power stations around the globe ensure that the world keeps moving. JCB3-80H High Performance MCBs will protect your infrastructure and therefore all your staff and machines involved in the production of electricity
5) The petrochemical industry
The chemical and petrochemical industry contributes significantly to everyday modern life. Whether you are talking about health, nutrition, clothing or mobility – their products ensure
quality of life and jobs. JCB3-80H High Performance MCBs, safeguard production on oil platforms in the sea as well as in production sites on land.
6) The steel industry
From kilometre-long bridges, through power station turbines subject to extreme loads to elegant high-rise buildings and stainless steel salad bowls: steel plays a major role in modern industry; its possible uses are boundless. JCB3-80H High Performance MCBs play an important role here
Technical Data
● Standard: IEC 60898-1, EN 60898-1
● Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A,80A
● Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N)
● Rated breaking capacity: 10kA
● Insulation voltage: 500V
● Rated impulse withstand voltage(1.2/50) : 4kV
● Thermo- magnetic release characteristic: B curve, C curve, D curve
● Mechanical life: 20,000 times
● Electrical life: 4000 times
● Protection degree: IP20
● Ambient temperature (with daily average ≤35℃):-5℃~+40℃
● Contact position indicator: Green=OFF, Red=ON
● Terminal connection type:Cable/U-type busbar/Pin-type busbar
● Mounting: On DIN rail EN 60715 ( 35mm) by means of fast clip device
● Recommended torque: 2.5N.m
● Combination with accessories: Auxiliary contact,Shunt release,Under voltage release, Alarm contact
Standard | IEC/EN 60898-1 | IEC/EN 60947-2 | |
Electrical features |
Rated current In (A) |
1, 2, 3, 4, 6, 10, 16,20, 25, 32, 40, 50, 63,80 |
|
Poles | 1P, 1P+N, 2P, 3P, 3P+N, 4P | 1P, 2P, 3P, 4P | |
Rated voltage Ue(V) | 230/400~240/415 | ||
Insulation voltage Ui (V) | 500 | ||
Rated frequency | 50/60Hz | ||
Rated breaking capacity | 10 kA | ||
Energy limiting class | 3 | ||
Rated impulse withstand voltage(1.2/50) Uimp (V) | 4000 | ||
Dielectric test voltage at ind. Freq. for 1 min (kV) | 2 | ||
Pollution degree | 2 | ||
Power loss per pole | Rated current (A) | ||
1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80 | |||
Thermo-magnetic release characteristic | B, C, D | 8-12In, 9.6-14.4In | |
Mechanical features |
Electrical life | 4, 000 | |
Mechanical life | 20, 000 | ||
Contact position indicator | Yes | ||
Protection degree | IP20 | ||
Reference temperature for setting of thermal element(℃) | 30 | ||
Ambient temperature (with daily average ≤35℃) | -5...+40 | ||
Storage temperation (℃) | -35...+70 | ||
Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar | |
Terminal size top/bottom for cable | 25mm2 / 18-4 AWG | ||
Terminal size top/bottom for Busbar | 10mm2 / 18-8 AWG | ||
Tightening torque | 2.5 N*m / 22 In-Ibs. | ||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | ||
Connection | From top and bottom | ||
Combination |
Auxiliary contact | Yes | |
Shunt release | Yes | ||
Under voltage release | Yes | ||
Alarm contact | Yes |