JCR3HM 2P 4P piranti saiki Sisa

Piranti saiki residual (rcd) JCR3HM, minangka piranti nylametake urip sing dirancang kanggo nyegah kejut listrik sing fatal yen sampeyan ndemek barang langsung, kayata kabel kosong.Uga bisa nyedhiyani sawetara pangayoman marang geni electrical.RCD JCR3HM kita nawakake tingkat perlindungan pribadi sing ora bisa diwenehake dening sekring lan pemutus sirkuit biasa.Padha cocok kanggo Aplikasi Industri, Komersial lan Domestik

Wuku JCR3HM RCCB

1. Nyedhiyakake pangayoman marang fault bumi uga sembarang bocor saiki

2. Otomatis medhot sirkuit nalika sensitivitas dirating wis ngluwihi

3. Nawakake kamungkinan mandap dual loro kanggo sambungan kabel lan busbar

4. Nawakake pangayoman marang fluktuasi voltase amarga kalebu piranti nyaring sing njaga tingkat voltase dilut.

Pambuka:

Piranti saiki residual (RCDs) JCR3HM dirancang kanggo nanggepi kanthi cepet marang aktivitas listrik sing ora normal lan ngganggu arus kanggo nyegah kejut listrik sing mbebayani.Piranti kasebut penting kanggo nglindhungi sistem listrik komersial lan omah.

JCR3HM Residual Current Circuit breaker RCCBs minangka piranti sing paling aman kanggo ndeteksi lan nglawan arus bocor listrik, saéngga njamin pangayoman marang kejut listrik sing disebabake kontak ora langsung.Piranti kasebut kudu digunakake kanthi seri kanthi MCB utawa sekring sing nglindhungi saka tekanan termal lan dinamis sing bisa ngrusak arus apa wae.Padha uga tumindak minangka switch pedhot utama ing hulu saka sembarang MCBs asale (contone, unit konsumen domestik).

JCR3HM RCCB minangka piranti safety listrik sing langsung mateni pasokan listrik nalika ndeteksi bocor sing bisa nyebabake kejut listrik.

Fungsi utama RCD JCR3HM kita yaiku kanggo ngawasi arus listrik lan ndeteksi anomali sing bisa mbebayani kanggo safety manungsa.Nalika cacat ing piranti dideteksi, RCD nanggepi mundhak lan langsung interrupts aliran saiki.Tanggepan cepet iki penting kanggo nyegah kacilakan listrik sing bisa ngancam nyawa.

JCR3HM RCD minangka piranti safety sensitif sing mateni listrik kanthi otomatis yen ana kesalahan.Ing lingkungan domestik, RCDs nyedhiyakake lapisan perlindungan ekstra marang bebaya listrik.Kanthi nambah panggunaan peralatan lan piranti ing omah modern, risiko kacilakan listrik mundhak.RCDs terus-terusan ngawasi aliran listrik lan tumindak minangka jaring pengaman, menehi katentreman atine sing duwe omah lan nyewo.

RCD JCR3HM dirancang kanggo nyukupi standar safety sing dhuwur lan menehi perlindungan sing dipercaya marang kejut listrik.Teknologi canggih lan presisi ndadekake komponen penting ing sistem safety listrik.RCD JCR3HM kanthi cepet ndeteksi lan nanggapi aktivitas listrik sing ora normal, nyedhiyakake tingkat proteksi sing ora ditandingi dening pemutus sirkuit lan sekring tradisional.

2 Pole JCR3HM RCCB digunakake ing cilik saka sambungan sumber siji-phase sing wis mung urip lan kabel netral.

4 Pole JCR3HM RCD digunakake ing cilik saka sambungan sumber telung phase.

asd (1)

Fitur sing paling penting

● Jinis elektromagnetik

● Proteksi bocor bumi

● Kapasitas breaking nganti 6kA

● Dirating saiki nganti 100A (kasedhiya ing 25A, 32A, 40A, 63A, 80A, 100A)

● Sensitivitas tripping: 30mA100mA, 300mA

● Tipe A utawa Tipe AC kasedhiya

● Kontak Indikasi Status Positif

● 35mm DIN alur soyo tambah

● keluwesan Instalasi karo pilihan saka sambungan line salah siji saka ndhuwur utawa ngisor

● Selaras karo IEC 61008-1,EN61008-1

 

Data Teknis

● Standar: IEC 61008-1,EN61008-1

● Jinis: Elektromagnetik

● Tipe (bentuk gelombang saka bocor bumi sensed): A utawa AC kasedhiya

● Kutub: 2 kutub, 1P+N, 4 kutub, 3P+N

● Rated saiki: 25A, 40A, 63A, 80A, 100A

● Rated tegangan kerja: 110V, 230V, 240V (1P + N);400v, 415V (3P+N)

● Rated sensitivitas ln: 30mA.100mA 300mA

● Dirating kapasitas bejat: 6kA

● Tegangan isolasi: 500V

● Dirating frekuensi: 50/60Hz

● Rated impuls tahan voltase (1.2/50): 6kV

● Tingkat polusi:2

● urip mekanik: 2000 kaping

● urip listrik: 2000 kaping

● Gelar pangayoman: IP20

● Suhu sekitar (kanthi rata-rata s35°C saben dina): -5C+40C

● Indikator posisi kontak: Green=OFF Red=ON

● Jinis sambungan terminal: Kabel / Pin-jinis busbar

● Pemasangan: Ing rel DIN EN 60715 ( 35mm) kanthi piranti klip cepet

● Rekomendasi torsi: 2.5Nm

● Sambungan: Saka ndhuwur utawa ngisor kasedhiya

asd (2)

Apa iku RCD?

Piranti listrik iki khusus dibangun kanggo mateni aliran arus listrik nalika ana bocor lemah dideteksi ing tingkat sing signifikan sing bisa mbebayani kanggo manungsa.RCD bisa ngoper aliran saiki sajrone 10 nganti 50 milidetik nalika ndeteksi kemungkinan bocor.

Saben RCD bakal terus-terusan ngawasi arus listrik sing mili liwat siji utawa luwih sirkuit.Aktif fokus ing ngukur kabel urip lan netral.Nalika ndeteksi arus listrik sing mili liwat loro kabel ora padha, RCD bakal mateni sirkuit kasebut.Iki nuduhake yen arus listrik duwe dalan sing ora disengaja sing bisa mbebayani, kayata wong sing ndemek kabel urip utawa piranti sing rusak.

Ing umume setelan omah, piranti proteksi iki digunakake ing kamar teles lan kanggo kabeh piranti supaya sing duwe omah aman.Padha uga becik kanggo njaga peralatan komersial lan industri aman saka kakehan listrik sing bisa ngrusak utawa malah miwiti geni listrik sing ora dikarepake.

Kepiye Sampeyan Nguji RCD?

Integritas RCD kudu dites kanthi rutin.Kabeh soket lan RCD tetep kudu dites saben telung sasi.Unit portabel kudu dites saben sampeyan nggunakake.Tes mbantu kanggo mesthekake yen RCD sampeyan bisa digunakake kanthi efisien lan bakal nglindhungi sampeyan saka bebaya listrik sing potensial.

Proses nguji RCD cukup gampang.Sampeyan pengin mencet tombol test ing ngarep piranti.Nalika sampeyan ngeculake, tombol kudu medhot arus energi saka sirkuit.

Pencet tombol mung ngrangsang kesalahan bocor bumi.Kanggo nguripake sirkuit maneh, sampeyan kudu nguripake saklar on/off bali menyang posisi urip.Yen sirkuit ora mateni, ana masalah karo RCD sampeyan.Luwih becik takon karo tukang listrik sing duwe lisensi sadurunge nggunakake sirkuit utawa piranti maneh.

Kepiye cara nyambungake RCD - DIAGRAM INSTALASI?

Sambungan piranti ampas-saiki relatif prasaja, nanging sawetara aturan kudu dituruti.RCD ora kudu digunakake minangka unsur siji ing antarane sumber daya lan beban.Iku ora nglindhungi saka short circuit utawa overheating saka kabel.Kanggo luwih safety, dianjurake kombinasi RCD lan sirkuit overcurrent, paling siji kanggo saben RCD.

Sambungake kabel fase (coklat) lan netral (biru) menyang input RCD ing sirkuit fase siji.Konduktor protèktif disambungake karo, contone, strip terminal.

Kawat fase ing output RCD kudu disambungake menyang pemutus sirkuit overcurrent, nalika kabel netral bisa disambungake langsung menyang instalasi.

Pesen kita