JCB1-125 Miniature Circuit Breaker 6kA/10kA
Brevis circuitus et cultro praesidio
Praevaricationem facultatem ad 10ka *
Cum contactu indicator
Modulus 27mm latitudo
Available from 63A to 125A
1 Pole , 2 poli , 3 poli , 4 pertica praesto sunt
B , C vel D curva
Parere IEC 60898-1
Introductio:
Circuitus ruptor JCB1-125 designatus est offerre gradum industrialem perficiendi altum, ambitum contra brevem ambitum munit et currenti onerare.6kA/10kA facultatem frangendi facit eam perfectam electionem in applicationibus commercialibus et gravibus industrialibus.
JCB1-125 ambitus ruptor factus est a summo gradu compositus.Hoc est curare firmitatem in omnibus applicationibus, quibus praesidium contra onerare et brevem circuitum exigitur.
Circuitus ruptor JCB1-125 est minor intentione multistandi minimi minimi ambitus ruptivi (MCB), currentis rate usque ad 125A.Frequentia 50Hz vel 60Hz est.Praesens habena viridis contactum spondet physice apertum et laborem in amni circuitu tuto exercendum concedit.Temperatura operativa est -30°C ad 70°C.Repositio temperatura -40°C ad 80°C
JCB1-125 Circuitus ruptor bonam intentionem habet sustinere facultatem.Habet patientiam electricam ascendentem ad quinque cyclos et mechanicam patientiam ascendentem usque ad 20000 cyclos.
Circuitus ruptor JCB1-125 integer cum 27mm latitudine polo et indicibus ON/Off.tonsum in 35mm DIN rail potest.Hoc genus pin busbar nexum terminatio habet
JCB1-125 ambitus ruptor pareat utrique vexillo industrialis IEC 60898-1, EN60898-1, AS/NZS 60898 et vexillum residentiale IEC60947-2, EN60947-2, AS/NZS 60947-2
JCB1-125 ambitus ruptor variis facultatibus fracturae praesto est, hi praevaricatores sunt perfectae electionis pro varietate applicationum.
Depictio producti:
Maxime features
Brevis circuitus et cultro praesidio
confractio facultatem:6ka, 10ka
27mm Latitudo per Pole
35mm DIN Rail Adscendens
Cum contactu indicator
Available from 63A to 125A
Ratus impetus sustinere intentionem (1.2/50) Uimp: 4000V
● 1 Pole , 2 poli , 3 poli , 4 pertica praesto sunt
Available in C et D curva
● Parere cum IEC 60898-1, EN60898-1, AS/NZS 60898 ac vexillum residentiale IEC60947-2, EN60947-2, AS/NZS 60947-2
Technical data
Standard: IEC 60898-1, EN 60898-1, IEC60947-2, EN60947-2
● Ratum current: \63A,80A,100A, 125A
Ratum intentione laborantis: 110V, 230V/240~ (1P, 1P + N), 400~ (3P,4P)
Rated fractionem facultatem: 6ka, 10kA
Insulatio voltage: 500V
Rated impulsus resistendi intentione (1.2/50) : 4kV
thermo- magnetica emissio propria: C curva, D curva
● Mechanica vita: 20000 times
Electrical vita: (IV) tempora
Praesidium gradum: IP20
● Ambiens temperatus (≤35℃ cotidie mediocris):-5℃~+40℃
Contact situ indicator: Viridis=OFF, Red=ON
Terminatio nexu generis: cable / pin genus busbar
Adscendens: On DIN rail EN 60715 (35mm) per ieiunium fabrica
commendatur torque: 2.5Nm
Standard | IEC/EN 60898-1 | IEC/EN 60947-2 | |
Electrical features | Ratum vena in (A) | 1, 2, 3, 4, 6, 10, 16; | |
20, 25, 32, 40, 50, 63, 80; | |||
Poloni | 1P, 1P+N, 2P, 3P, 3P+N, 4P | 1P, 2P, 3P, 4P . | |
Rated voltage Ue (V) | 230/400~240/415 | ||
Nulla voltage Ui (V) | 500 | ||
Rated frequency | 50/60Hz | ||
Rated facultatem fractionis | 10 KA | ||
Energy cautum genus | 3 | ||
Ratum impetus sustinere intentionis (1.2/50) Uimp (V) | 4000 | ||
Dielectric test voltage in ind.Freq.for 1 min (kV) | 2 | ||
Pollutio gradus | 2 | ||
Potestas damnum per polum | Ratum est vena (A) | ||
1, 2, 3, 4, 5, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63, 80; | |||
Thermo-magnetica release natura | B, C, D | 8-12In, 9.6-14.4In | |
Mechanica features | Vita electrica | 4, 000 | |
Mechanica vita | 20, 000 | ||
Contact situ indicator | Ita | ||
Praesidium gradum | IP20 | ||
Reference temperatus ad occasum elementum scelerisque (℃) | 30 | ||
Ambiens temperatus (≤35 cotidie mediocris) | -5...+40 | ||
Temperatio repono (℃) | -35...+70 | ||
Institutionem | Terminatio nexu generis | Cable/U-type busbar/pin-type busbar | |
Terminatio magnitudinis top / imo ad funem | 25mm2 / 18-4 AWG | ||
Terminatio magnitudinis top / imo ad Busbar | 10mm2 / 18-8 AWG | ||
tensus tensus | 2.5 N*m/22 In-Ibs. | ||
Adscendens | On DIN rail EN 60715 (35mm) ope clip fabrica | ||
Connection | A summis | ||
Compositum | Contactus auxiliaris | Ita | |
Shunt emissio | Ita | ||
Sub voltage emissio | Ita | ||
Terror contactus | Ita |
Ex Characteribus Tripping, MCB in promptu sunt curvae "B", "C" et "D" ad diversas applicationes accommodatae.
"B" Curve - tutelae circuitus electricae cum apparatu quod currentem aestum non causat (circuitus accensis et distributio).Brevis circuitus emissio ad (3-5) In.
"C" Curve - tutelae circuitus electricorum cum apparatu qui agit fluctuationem (inductionem onerum et circuitus motoris) brevi ambitus emissio ponitur ad (5-10) In.
"D" Curve - tutelae circulorum electricorum, qui venam accursum altam faciunt, plerumque 12-15 vicibus thermas current aestimatae (transformat, machinas x-ray etc).Brevis circuitus emissio ad (10-20) In.