News

Learn about wanlai latest company developments and industry information

JCR3HM 2P and 4P Residual Current Device: A Comprehensive Overview

Nov-26-2024
wanlai electric

Modern electrical systems concern have been placed on the highest safety baseline. The JCR3HM Rcd Breaker have a huge role in safety in electrical areas by avoiding any fatal electric shocks or electrical fires. These devices are critical in industrial, commercial, and residential uses, where the capabilities that come with these devices surpass the abilities of normal fuses and rcd protection As for the JCR3HM RCDs that are mainly after the MCCBs, especially the RCCBs, the application is of quickly reacting to abnormally high current such as earth faults or the leakage currents. If such deformations strike, the RCD halts the current, thus reducing the risk of accidents and the subsequent loss of lives and property.

1

Benefits of JCR3HM RCCB

The JCR3HM RCCBs are safety devices intended to suppress electrical fault menace that may pose a fatal risk to life and property. They provide enhanced protection compared to the other two by not only leaking and interrupting leakage currents, and as well earth faults that could potentially cause fatal electric shocks or electrical fires. These include the JCR 3HM RCCBs for industrial, commercial as well as domestic use since they are safer than other devices such as fuses and rcd circuit breaker

  • Protection Against Earth Fault and Leakage Current: Regarding Earth faults and leakage currents, the JCR3HM RCCBs are designed to detect them well. This helps to make sure that any even insignificant losses which might otherwise be ignored are quickly recognized and rectified.
  • Automatic Disconnection: These devices usually have a tendency of switching off their circuit once the degree of sensitivity is achieved. This rapid disconnection is important in order to minimize the risk of electric shopping hazard, fire hazards etc.
  • Dual Termination: The JCR3HM RCCBs have features that allow for dual break options where they can be either connected by cables or busbars.
  • Voltage Fluctuation Protection: Uninterrupted voltages are maintained throughout the electrical system through a filtering device which reduces the risk of transient voltage levels being experienced throughout the electrical circuit of the system.

2

Applications

JCR3HM RCCBs are versatile and suitable for a wide range of applications, including:

  • Industrial Settings: He has made protecting heavy machinery and equipment from any electrical faults as one of his primary objectives.
  • Commercial Buildings: Offices and shops or any other commercial residential and industrial properties are areas that require protective circuits installed to make sure that the electrical systems are safe.
  • Domestic Use: Recreation- protection from electrical shocks and fire in homes thereby ensuring that homes are safe.

Key Features

The JCR3HM RCCBs come equipped with numerous features that enhance their performance and reliability:

  • Electromagnetic Type: Ensures reliable operation by responding to electrical faults with precision.
  • Earth Leakage Protection: This aspect offers good shield against earth leakages hence reducing the dangers associated with electric shocks exceptionally.
  • High Breaking Capacity: With up to 6kA rating, it is resistant to overload to meet most demands placed on it at any one time.
  • Rated Current Range: Comes in various standard current ratings, which include 25A, 32A, 40A, 63A, 80A, 100A to suit the variety of electrical loads present.
  • Tripping Sensitivity: Available with sensitivities of 30mA, 100mA and 300mA allowing a rapid reaction with the leakage currents to which it is exposed.
  • Type A or Type AC: It exist as type A and type AC to suit any form of leakage current in the circuit.
  • Positive Status Indication Contact: Clear indication of the contact status with safety measures for safety and effectiveness in use.
  • 35mm DIN Rail Mounting: Easy and secure installation on standard DIN rails.
  • Flexible Installation: Line connection can be made from either the top or bottom, providing flexibility during installation.
  • Compliance with Standards: Compliant with IEC 61008-1 and EN61008-1 interfaces that guarantee high levels of safety and performance.

Technical Data

The JCR3HM RCCBs are designed to meet rigorous technical specifications:

  • Standard: IEC 61008-1, EN61008-1
  • Type: Electromagnetic
  • Poles: Today, it is available in 2 pole (1P+N) and 4 pole (3P+N) current configurations.
  • Rated Current: The following related areas were identified: 25A, 40A, 63A, 80A, 100A
  • Rated Working Voltage: AC ~110V 230V 240V (1P with N) ; ~ 400V, 415V (3P with N)
  • Rated Sensitivity (In): Feedback outputs of 30mA, 100mA and 300mA
  • Rated Breaking Capacity: 6kA
  • Insulation Voltage: 500V
  • Rated Frequency: 50/60Hz
  • Rated Impulse Withstand Voltage (1.2/50): 6kV
  • Pollution Degree: 2
  • Mechanical Life: 2000 operations
  • Electrical Life: 2000 operations
  • Protection Degree: IP20
  • Ambient Temperature Range: -5?C to +40?C (with daily average ≤ 35?C)
  • Contact Position Indicator: Green (OFF), Red (ON)
  • Terminal Connection Type: Cable/Pin-type busbar
  • Mounting: DIN rail EN 60715 (35mm) with a fast clip device
  • Recommended Torque: 2.5N.m
  • Connection: Flexible with options for top or bottom connections

The JCR3HM rcd protected circuits are essential for modern electrical safety systems. Their ability to detect and respond to earth faults and leakage currents makes them invaluable in preventing electric shocks and potential fire hazards. With robust features, high reliability, and compliance with international standards, the JCR3HM RCCBs provide unparalleled protection for industrial, commercial, and domestic electrical installations. Investing in JCR3HM RCD is a proactive step towards ensuring electrical safety and peace of mind.

 

Message us

You May Also Like